Woodward 8440-2028 IKD1M 8DI/8DO Expansion Module
In stock, ready to ship
Manufacturer: Woodward
Product No.: 8440-2028
Product Type: IKD1M Digital I/O Expansion Module
Product Origin: USA
Payment: T/T
Weight: 1200g
Shipping port: Xiamen
Warranty: 12 months
Yes, we provide a 30-day money-back guarantee for all purchases.
Yes, all items come with a 12-month warranty from the date of shipment.
Product Overview
The Woodward 8440-2028 is an IKD1M digital I/O expansion module designed for Woodward generator control and power management systems. It provides eight digital inputs and eight digital outputs through a CAN-based communication interface. The module expands the discrete signal capacity of compatible controllers and supports external status monitoring and control functions.
Key Specs
- Manufacturer: Woodward
- Model: 8440-2028
- Product type: IKD1M digital I/O expansion module
- Digital inputs: 8
- Digital outputs: 8
- Communication: CAN bus
- Application: External digital I/O expansion
- Compatible systems: Designated Woodward easYgen and generator control systems
Why Choose This
- Expands available digital input and output points.
- Supports remote discrete signal integration through CAN communication.
- Provides additional control and status interfaces for generator systems.
- Suitable for distributed I/O arrangements in compatible Woodward installations.
Common Questions
Q: How many I/O points does 8440-2028 provide?
A: It provides eight digital inputs and eight digital outputs.
Q: Can it be used with easYgen-3000XT?
A: Yes. It can be used for external digital I/O expansion with compatible easYgen-3000XT configurations. The CAN ID must be configured for the applicable system.
Q: Is it interchangeable with 8440-2116?
A: The two IKD1M versions use the same basic hardware platform, but their default CAN ID configurations differ. The 8440-2028 requires CAN ID configuration for the applicable easYgen installation.
Mounting Steps
- Verify controller compatibility and the required number of expansion modules.
- Mount the IKD1M module in the designated cabinet location.
- Connect the CAN communication cable and module power supply.
- Wire the eight digital inputs and eight digital outputs according to the terminal diagram.
- Configure the CAN ID and I/O assignments using the applicable Woodward configuration tool.
- Verify communication and individual I/O operation.
Buying Advice
Choose 8440-2028 when eight additional digital inputs and eight digital outputs are required in a compatible Woodward control system. Check CAN ID settings, controller software compatibility, and the expansion network configuration. Do not assume its default CAN address matches the 8440-2116 version.