Woodward
ProTech-GII HV/HV Voted Relay Overspeed Protection – 8237-1597
Only 6 products left
Manufacturer: Woodward
Product No.: 8237-1597
Product Type: ProTech-GII Overspeed Protection System
Product Origin: USA
Payment: T/T
Weight: 1100g
Shipping port: Xiamen
Warranty: 12 months
Yes, we provide a 30-day money-back guarantee for all purchases.
Yes, all items come with a 12-month warranty from the date of shipment.
Product Overview
The Woodward 8237-1597 is a ProTech-GII overspeed protection system in a bulkhead-mount HV/HV configuration with voted relays. It monitors turbine speed through redundant sensing and voting logic to provide independent overspeed protection and trip functions. The unit is designed for turbine safety applications where reliable detection and shutdown response are required.
Key Specs
- Manufacturer: Woodward
- Model: 8237-1597
- Product family: ProTech-GII
- Mounting: Bulkhead mount
- Input configuration: HV/HV
- Relay configuration: Voted relays
- Application: Turbine overspeed protection
- Product status: Non-preferred model for existing installations and spares
- Preferred successor: 8237-2597
Why Choose This
- Provides dedicated overspeed protection for turbine applications.
- Uses a voted relay configuration for trip output logic.
- HV/HV configuration supports the specified high-voltage speed input arrangement.
- Bulkhead mounting supports installation in the designated control cabinet.
- Suitable for maintaining existing ProTech-GII installations.
Common Questions
Q: What does HV/HV mean?
A: It identifies the high-voltage input configuration for both designated speed sensing channels.
Q: What is the difference between 8237-1597 and 8237-2597?
A: Both have the bulkhead-mount HV/HV voted-relay configuration. The 8237-2597 is the preferred successor model.
Q: Can an existing configuration file be transferred to the successor?
A: Woodward ProTech-GII service documentation provides conversion procedures. Compatibility depends on the unit revision and service-tool version.
Mounting Steps
- Confirm the existing ProTech-GII mounting and input configuration.
- Verify the HV/HV sensor wiring and relay output arrangement.
- Isolate the protection system according to the turbine safety procedure.
- Install the module and reconnect the speed sensing and trip circuits.
- Perform the prescribed overspeed protection test before returning the turbine to service.
Buying Advice
Select 8237-1597 for an existing ProTech-GII bulkhead-mount HV/HV voted-relay installation. For new installations, evaluate the preferred 8237-2597 model. Confirm hardware revision, configuration compatibility, trip wiring, and conversion requirements before ordering.