GE

PROFIBUS-DP Slave Interface Module GE Fanuc IC200BEM002

Only 8 products left

  • Manufacturer: GE

  • Product No.: IC200BEM002

  • Product Type: VersaMax PROFIBUS-DP Slave Communication Module

  • Product Origin: USA

  • Payment: T/T

  • Weight: 1100g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The GE Fanuc IC200BEM002 is a VersaMax PROFIBUS-DP Network Slave Module. It connects a VersaMax PLC system to a PROFIBUS-DP network, allowing the PLC CPU to exchange reference table data with a PROFIBUS master. The module installs on the IC200CHS006 communications carrier.

Key Specs

  • Product family: VersaMax
  • Module type: PROFIBUS-DP Network Slave
  • Network protocol: PROFIBUS-DP
  • Network data rate: 9.6 kbaud to 12 Mbaud
  • Baud rate detection: Automatic
  • Station address: 1–125, software configurable
  • Maximum stations: Up to 125 per network
  • Data capacity: 384 bytes combined input and output data
  • Maximum input data: 244 bytes
  • Maximum output data: 244 bytes
  • Network connector: 9-pin D-sub
  • Required carrier: IC200CHS006

Why Choose This

  • Provides PROFIBUS-DP connectivity for VersaMax PLC systems.
  • Supports automatic network baud-rate detection.
  • Transfers PLC reference table data through the PROFIBUS network.
  • Supports multiple network slave modules in one VersaMax PLC system.
  • Provides a dedicated communication interface for distributed automation architectures.

Common Questions

Is IC200BEM002 a PROFIBUS master or slave?

It is a PROFIBUS-DP slave module. A separate PROFIBUS master controls network communication.

Which carrier does it require?

It requires the IC200CHS006 communications carrier for installation.

What is the difference between IC200BEM002 and IC200BEM003?

IC200BEM002 operates as a PROFIBUS-DP slave, while IC200BEM003 operates as a PROFIBUS-DP master. They are not interchangeable communication roles.

Mounting Steps

  1. Install the IC200CHS006 communications carrier in the VersaMax system.
  2. Mount the IC200BEM002 module onto the carrier.
  3. Connect the PROFIBUS cable through the 9-pin D-sub interface.
  4. Configure the station address and network parameters.
  5. Verify communication status and data exchange with the PROFIBUS master.

Buying Advice

Confirm that the application requires a PROFIBUS-DP slave module rather than a master. Check the existing carrier, network address configuration, GSD file, and required input/output data size before ordering.