EGCP-2 Generator Control – Woodward 8406-121

In stock, ready to ship

  • Manufacturer: Woodward

  • Product No.: 8406-121

  • Product Type: EGCP-2 Engine Generator Control Package

  • Product Origin: USA

  • Payment: T/T

  • Weight: 1700g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The Woodward 8406-121 is an EGCP-2 Engine Generator Control Package with a 50–150 VAC potential transformer input range. It is a microprocessor-based controller designed for generator set control, synchronization, protection, and load management. The EGCP-2 supports standalone and utility-parallel generator applications, as well as coordinated operation of multiple generator sets.

Key Specs

  • Manufacturer: Woodward
  • Model: 8406-121
  • Product family: EGCP-2
  • Product type: Engine Generator Control Package
  • PT input range: 50–150 VAC RMS
  • Supply voltage: 9–32 VDC
  • Maximum power consumption: 20 W
  • CT input: 0–6 A RMS
  • Generator frequency range: 40–70 Hz
  • Magnetic pickup input: 100–15,000 Hz
  • Discrete inputs: 8
  • Process input: 4–20 mA or 1–5 VDC
  • Communication: RS-485 and RS-422
  • Relay outputs: 10 A at 250 VAC resistive or 10 A at 30 VDC resistive
  • Operating temperature: -20 to +70 °C

Why Choose This

  • Combines engine management and generator control functions.
  • Supports automatic start and stop sequencing.
  • Provides generator synchronization and load sharing functions.
  • Supports utility-parallel and multiple generator applications.
  • Includes Modbus communication capability for system integration.

Common Questions

Q: What is the difference between 8406-120 and 8406-121?
A: The 8406-121 accepts a 50–150 VAC PT input, while the 8406-120 accepts a 150–300 VAC PT input.

Q: Can it control multiple generator sets?
A: Yes. An EGCP-2 network can coordinate up to eight generator sets in supported applications.

Q: Does it support load sharing?
A: Yes. It supports real and reactive load control functions for compatible generator configurations.

Mounting Steps

  1. Confirm that the generator voltage sensing range matches the 50–150 VAC PT input version.
  2. Install the EGCP-2 in the designated control panel.
  3. Connect the 9–32 VDC supply and protective earth.
  4. Wire PT, CT, magnetic pickup, process inputs, relay outputs, and communication interfaces.
  5. Configure generator parameters, synchronization, protection, and load management settings.
  6. Complete commissioning and generator protection tests before operation.

Buying Advice

Select 8406-121 for EGCP-2 installations requiring a 50–150 VAC PT input. Check generator voltage sensing, CT input, control supply, communication requirements, and application settings. Do not substitute 8406-120 unless the PT input range is suitable for the installation.