Bently Nevada

Bently Nevada 330130-00-05-10-02-CN 3300 XL 8 mm Proximity Probe

In stock, ready to ship

  • Manufacturer: Bently Nevada

  • Product No.: 330130-00-05-10-02-CN

  • Product Type: 3300 XL 8 mm Proximity Probe

  • Product Origin: USA

  • Payment: T/T

  • Weight: 323g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Description

The 330130-00-05-10-02-CN is an 8 mm standard mount proximity probe from the Bently Nevada 3300 XL series, engineered for precise, non-contact measurement of radial vibration and axial shaft position in critical rotating machinery. Ideal for gas turbines, high-speed compressors, and large pumps, this probe delivers consistent linearity and signal stability essential for machine condition monitoring and protection.

Constructed with AISI 303/304 stainless steel and a polyphenylene sulfide (PPS) tip, the probe is designed for long-term durability in harsh industrial environments. The ClickLoc™ miniature coaxial connector ensures a secure, low-impedance connection, maintaining signal integrity even under high-vibration conditions.


Technical Specifications

Specification Details
Model Designation 330130-00-05-10-02-CN
Probe Series 3300 XL 8 mm
Total Length 1.0 meter (3.3 ft)
Mount Type Standard Mount
Connector Type Miniature ClickLoc™ coaxial
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 303/304 Stainless Steel

Operational Reliability

The 3300 XL system is designed for interchangeable probes and cables, allowing replacement without recalibration. The ClickLoc™ connector ensures a vibration-resistant, low-noise connection, delivering high-fidelity shaft displacement and vibration data for real-time condition monitoring and predictive maintenance.


Frequently Asked Questions

What does the "CN" suffix indicate?
It refers to regional agency approvals or certifications applicable to the installation environment.

Can I replace this probe without recalibrating my monitoring system?
Yes, probes in the 3300 XL 8 mm series are fully interchangeable, maintaining calibrated accuracy when replaced.

How is this probe mounted?
The standard-mount configuration allows threading into a mounting bracket, with the tip positioned at a precisely adjusted gap relative to the rotating shaft.

Link copied