ABB 1SAM250000R1003 Manual Motor Starter
In stock, ready to ship
Manufacturer: ABB
Product No.: 1SAM250000R1003
Product Type: manual motor starter
Product Origin: USA
Payment: T/T
Weight: 760g
Shipping port: Xiamen
Warranty: 12 months
Yes, we provide a 30-day money-back guarantee for all purchases.
Yes, all items come with a 12-month warranty from the date of shipment.
Extended Product Type: MS116-0.4
Product ID: 1SAM250000R1003
EAN: 4013614320262
Catalog Description: MS116-0.4 Manual Motor Starter 0.25 … 0.40 A
Long Description:
The MS116-0.4 manual motor starter (also known as a motor protection circuit breaker or manual motor protector) is a compact 45 mm-wide device with a rated operational current of Ie = 0.40 A.
It is used to manually switch motors on and off and to protect them—without the need for a fuse—against short-circuits, overload, and phase failures.
The device offers a rated service short-circuit breaking capacity (Ics) of 50 kA at 400 VAC and a trip class of 10A.
Additional features include a built-in disconnect function, temperature compensation, trip-free mechanism, and a rotary handle with clear switch position indication.
The motor starter is suitable for both three-phase and single-phase applications.
Accessories such as auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase busbars, power in-feed blocks, and locking devices for protection against unauthorized adjustments are available.
Dimensions
-
Product Net Width: 45 mm
-
Product Net Height: 90 mm
-
Product Net Depth / Length: 85.6 mm
-
Product Net Weight: 0.225 kg
Technical Specifications
Short-Circuit Breaking Capacity
-
Rated Service Short-Circuit Breaking Capacity (Ics):
-
230 V AC: 50 kA
-
400 V AC: 50 kA
-
440 V AC: 50 kA
-
500 V AC: 30 kA
-
690 V AC: 30 kA
-
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
-
230 V AC: 100 kA
-
400 V AC: 100 kA
-
440 V AC: 100 kA
-
500 V AC: 100 kA
-
690 V AC: 100 kA
Electrical Characteristics
-
Rated Instantaneous Short-Circuit Current Setting (Ii): 5 A
-
Setting Range: 0.25 … 0.40 A
-
Rated Operational Power AC-3 (Pe):
-
400 V, Three-Phase: 0.09 kW
-
Rated Operational Power AC-3e (Pe):
-
400 V, Three-Phase: 0.09 kW
-
Rated Operational Voltage: 690 V AC (main circuit)
-
Rated Operational Current (Ie): 0.4 A
-
Rated Operational Current AC-3 / AC-3e: 0.4 A
-
Rated Frequency: 50 Hz / 60 Hz
-
Rated Impulse Withstand Voltage (Uimp): 6 kV
-
Rated Insulation Voltage (Ui): 690 V
-
Power Loss (per pole at rated conditions): 0.6 … 1.7 W
-
Number of Poles: 3P
-
Conventional Free-Air Thermal Current (Ith): 0.4 A
Protection & Durability
-
Degree of Protection:
-
Housing: IP20
-
Main Circuit Terminals: IP10
-
Pollution Degree: 3
-
Electrical Durability: 100,000 cycles
-
Mechanical Durability: 100,000 operations
Terminals & Connections
-
Terminal Type: Screw terminals
-
Connecting Capacity (Main Circuit):
-
Flexible with ferrule: 1/2× 0.75 … 2.5 mm²
-
Flexible with insulated ferrule: 1/2× 0.75 … 2.5 mm²
-
Flexible: 1/2× 0.75 … 2.5 mm²
-
Rigid: 1/2× 1 … 4 mm²
-
Tightening Torque (Main Circuit): 0.8 … 1.2 N·m
-
Wire Stripping Length: 9 mm
-
Recommended Screwdriver: Pozidriv 2
Mounting
-
Actuator Type: Rotary handle
-
Contact Position Indication: ON / OFF
-
Mounting Position: Any (1 … 6)
-
DIN Rail Mounting:
-
TH35-15 (35 × 15 mm), IEC 60715
-
TH35-7.5 (35 × 7.5 mm), IEC 60715
Minimum Mounting Distances
-
Conductive Board, Horizontal:
-
Up to 400 V: 0 mm
-
Up to 690 V: 1.5 mm
-
Conductive Board, Vertical: 75 mm
-
Other Devices (Same Type):
-
Horizontal: 0 mm
-
Vertical: 150 mm
Standards
-
IEC/EN 60947-1
-
IEC/EN 60947-2
-
IEC/EN 60947-4-1
-
UL 60947-1
-
UL 60947-4-1
-
IEC 60335-2-40 A2L