Bently Nevada
330103-00-06-10-02-05 330103 | Bently Nevada | Proximity Probe
In stock, ready to ship
Manufacturer: Bently Nevada
Product No.: 330103-00-06-10-02-05
Product Type: 8 mm Proximity Probe Sensor
Product Origin: USA
Payment: T/T
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Yes, we provide a 30-day money-back guarantee for all purchases.
Yes, all items come with a 12-month warranty from the date of shipment.
Product Description
The 330103-00-06-10-02-05 is a high-precision 8 mm eddy current proximity probe within the Bently Nevada 3300 XL series. It is designed for non-contacting vibration and displacement monitoring on fluid-film bearing machines. The probe produces a linear voltage output proportional to the gap between the probe tip and the target material.
Engineered for harsh industrial environments, this probe offers enhanced chemical resistance, robust mechanical construction, and minimized temperature-induced drift. It is fully compatible with 3300 XL Proximitor sensors and extension cables, enabling seamless integration with machinery protection systems such as the Bently Nevada 3500 series.
Technical Specifications
| Feature | Specification |
|---|---|
| Probe Diameter | 8 mm |
| Thread Type | 3/8-24 UNF-2A (standard housing) |
| Unthreaded Barrel Length | 0.0 inches |
| Overall Case Length | 0.6 inches |
| Total Cable Length | 1.0 m (3.3 ft) |
| Connector Type | Miniature coaxial Click-Loc |
| Linear Range | 2 mm (80 mils), starting at 0.25 mm (10 mils) from tip |
| Scale Factor | 7.87 V/mm (200 mV/mil) |
| Operating Temperature | -51 °C to +177 °C (-60 °F to +351 °F) |
| Target Material | AISI 4140 steel (calibration standard) |
Common Applications
-
Radial vibration monitoring on centrifugal compressors
-
Axial (thrust) position sensing in steam turbines
-
Shaft eccentricity and phase reference (Keyphasor) detection
-
Industrial gearbox condition monitoring
Frequently Asked Questions
Can this probe be used with older 3300 series cables?
-
While physically compatible, it is recommended to use 3300 XL components only to ensure full linear range and proper frequency response.
Does the “02” total length option affect calibration?
-
Yes. The 1.0-meter probe is calibrated for a specific electrical length and should be paired with a 4.0 m or 8.0 m extension cable to achieve the required 5.0 m or 9.0 m system length.