{"product_id":"bently-nevada-330105-02-12-05-02-00-3300-xl-8-mm-reverse-mount-probe","title":"Bently Nevada 330105-02-12-05-02-00 3300 XL 8 mm Reverse Mount Probe","description":"\u003ch3\u003eTechnical Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330105-02-12-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereverse-mount proximity probe\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada’s 3300 XL series\u003c\/strong\u003e, specifically engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft radial vibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaxial position\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasurement in space-constrained machinery. Unlike standard probes that pass through the machine casing, this reverse-mount design allows the probe to be installed from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einside of the bearing housing\u003c\/strong\u003e, facing outward. It is ideal for applications in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esmaller centrifugal pumps\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egearboxes\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especialized turbomachinery\u003c\/strong\u003e. The probe uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance eddy-current technology\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecise\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elinear voltage outputs\u003c\/strong\u003e, even in environments filled with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elubricants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eOrdering Specification Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330105 (8 mm Reverse Mount Proximity Probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02 (0.5 meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 (12 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Length Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e05 (0.5 meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\/Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02 (Miniature coaxial ClickLoc connector, standard cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e00 (Not required\/Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (80 mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Tip Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe Case Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAISI 303\/304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThread Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClickLoc miniature coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Application\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330105-02-12-05-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econdition monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein systems where the probe must be mounted\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternally\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebearing cap\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esupport housing\u003c\/strong\u003e. By enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enon-contact measurement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof shaft dynamics, it provides real-time data on critical machine health parameters, such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erotor vibration amplitude\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft centerline position\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebearing clearance degradation\u003c\/strong\u003e. This is essential for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epredictive maintenance\u003c\/strong\u003e, allowing engineers to identify issues like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emisalignment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erotor instability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebefore they lead to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eunplanned downtime\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem failure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the 330105 and 330104 models?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereverse mounting\u003c\/strong\u003e, allowing for installation from the inside of a bearing housing, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis intended for standard through-case mounting. Although both probes have similar internal electrical characteristics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330105\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas a different case geometry optimized for reverse-mount applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this probe be used in hazardous area applications?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix indicates that this specific probe does\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehave approvals for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehazardous areas\u003c\/strong\u003e. For applications that require\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATEX\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIECEx\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecertification for explosive atmospheres, an alternate model with the appropriate certifications should be selected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 0.5-meter cable length sufficient for most installations?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5-meter cable length\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically adequate for installations where the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProximitor sensor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis positioned in close proximity to the probe, such as inside a common terminal housing or specialized equipment junction box. For longer distances, a longer cable length may be needed.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":47778731622538,"sku":"330105-02-12-05-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/2818\/2154\/files\/3301042.jpg?v=1772516822","url":"https:\/\/www.cambiaplc.com\/products\/bently-nevada-330105-02-12-05-02-00-3300-xl-8-mm-reverse-mount-probe","provider":"Controlix Automation","version":"1.0","type":"link"}