{"product_id":"bently-nevada-21000-16-10-00-124-03-02-vibration-sensor","title":"Bently Nevada 21000-16-10-00-124-03-02 Vibration Sensor","description":"\u003ch2 data-start=\"109\" data-end=\"133\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"134\" data-end=\"779\"\u003eThe \u003cstrong data-start=\"138\" data-end=\"180\"\u003eBently Nevada 21000-16-10-00-124-03-02\u003c\/strong\u003e is a \u003cstrong data-start=\"186\" data-end=\"231\"\u003eheavy-duty 16 mm proximity probe assembly\u003c\/strong\u003e designed for \u003cstrong data-start=\"245\" data-end=\"303\"\u003ehigh-precision vibration and shaft position monitoring\u003c\/strong\u003e in large-scale industrial rotating machinery. Its \u003cstrong data-start=\"354\" data-end=\"378\"\u003e16 mm probe diameter\u003c\/strong\u003e provides a significantly \u003cstrong data-start=\"404\" data-end=\"426\"\u003ewider linear range\u003c\/strong\u003e than standard 8 mm probes, making it ideal for \u003cstrong data-start=\"474\" data-end=\"545\"\u003eturbines, compressors, and other machines with large shaft movement\u003c\/strong\u003e. The probe is mounted in an \u003cstrong data-start=\"574\" data-end=\"594\"\u003ealuminum housing\u003c\/strong\u003e that supports \u003cstrong data-start=\"609\" data-end=\"681\"\u003eexternal installation, gap adjustment, and hazardous area compliance\u003c\/strong\u003e, protecting the sensor from harsh industrial environments while enabling convenient field access.\u003c\/p\u003e\n\u003chr data-start=\"781\" data-end=\"784\"\u003e\n\u003ch2 data-start=\"786\" data-end=\"813\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"815\" data-end=\"1537\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"815\" data-end=\"844\"\u003e\n\u003ctr data-start=\"815\" data-end=\"844\"\u003e\n\u003cth data-start=\"815\" data-end=\"827\" data-col-size=\"sm\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"827\" data-end=\"844\" data-col-size=\"md\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"875\" data-end=\"1537\"\u003e\n\u003ctr data-start=\"875\" data-end=\"934\"\u003e\n\u003ctd data-start=\"875\" data-end=\"892\" data-col-size=\"sm\"\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd data-start=\"892\" data-end=\"934\" data-col-size=\"md\"\u003e16 mm (high-range eddy-current sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"935\" data-end=\"981\"\u003e\n\u003ctd data-start=\"935\" data-end=\"961\" data-col-size=\"sm\"\u003eUnthreaded Length (-16)\u003c\/td\u003e\n\u003ctd data-start=\"961\" data-end=\"981\" data-col-size=\"md\"\u003e1.6 in (40.6 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"982\" data-end=\"1029\"\u003e\n\u003ctd data-start=\"982\" data-end=\"1009\" data-col-size=\"sm\"\u003eCase Thread Length (-10)\u003c\/td\u003e\n\u003ctd data-start=\"1009\" data-end=\"1029\" data-col-size=\"md\"\u003e1.0 in (25.4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1030\" data-end=\"1097\"\u003e\n\u003ctd data-start=\"1030\" data-end=\"1056\" data-col-size=\"sm\"\u003eTotal Lead Length (-00)\u003c\/td\u003e\n\u003ctd data-start=\"1056\" data-end=\"1097\" data-col-size=\"md\"\u003eStandard lead for housing integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1098\" data-end=\"1148\"\u003e\n\u003ctd data-start=\"1098\" data-end=\"1127\" data-col-size=\"sm\"\u003eTotal System Length (-124)\u003c\/td\u003e\n\u003ctd data-start=\"1127\" data-end=\"1148\" data-col-size=\"md\"\u003e12.4 m (≈40.7 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1149\" data-end=\"1220\"\u003e\n\u003ctd data-start=\"1149\" data-end=\"1174\" data-col-size=\"sm\"\u003eConnector Option (-03)\u003c\/td\u003e\n\u003ctd data-start=\"1174\" data-end=\"1220\" data-col-size=\"md\"\u003eMiniature coaxial connector with protector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1221\" data-end=\"1297\"\u003e\n\u003ctd data-start=\"1221\" data-end=\"1246\" data-col-size=\"sm\"\u003eAgency Approvals (-02)\u003c\/td\u003e\n\u003ctd data-start=\"1246\" data-end=\"1297\" data-col-size=\"md\"\u003eCSA, ATEX, IECEx (hazardous location certified)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1298\" data-end=\"1335\"\u003e\n\u003ctd data-start=\"1298\" data-end=\"1313\" data-col-size=\"sm\"\u003eLinear Range\u003c\/td\u003e\n\u003ctd data-start=\"1313\" data-end=\"1335\" data-col-size=\"md\"\u003e~4.0 mm (160 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1336\" data-end=\"1401\"\u003e\n\u003ctd data-start=\"1336\" data-end=\"1360\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"1360\" data-end=\"1401\" data-col-size=\"md\"\u003e-35 °C to +177 °C (-31 °F to +351 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1402\" data-end=\"1474\"\u003e\n\u003ctd data-start=\"1402\" data-end=\"1418\" data-col-size=\"sm\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd data-start=\"1418\" data-end=\"1474\" data-col-size=\"md\"\u003eReverse-mount probe for external housing integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1475\" data-end=\"1537\"\u003e\n\u003ctd data-start=\"1475\" data-end=\"1494\" data-col-size=\"sm\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd data-start=\"1494\" data-end=\"1537\" data-col-size=\"md\"\u003eAluminum, heavy-duty protective housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1539\" data-end=\"1542\"\u003e\n\u003ch2 data-start=\"1544\" data-end=\"1570\"\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cul data-start=\"1572\" data-end=\"1928\"\u003e\n\u003cli data-start=\"1572\" data-end=\"1651\"\u003e\n\u003cp data-start=\"1574\" data-end=\"1651\"\u003e\u003cstrong data-start=\"1574\" data-end=\"1615\"\u003eCritical machinery protection systems\u003c\/strong\u003e (e.g., Bently Nevada 3500 Series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1652\" data-end=\"1747\"\u003e\n\u003cp data-start=\"1654\" data-end=\"1747\"\u003eMonitoring \u003cstrong data-start=\"1665\" data-end=\"1702\"\u003eaxial thrust and radial vibration\u003c\/strong\u003e in turbines, compressors, and large motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1748\" data-end=\"1845\"\u003e\n\u003cp data-start=\"1750\" data-end=\"1845\"\u003eApplications requiring \u003cstrong data-start=\"1773\" data-end=\"1802\"\u003elarge probe-to-shaft gaps\u003c\/strong\u003e or measurement through \u003cstrong data-start=\"1826\" data-end=\"1843\"\u003ethick casings\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1846\" data-end=\"1928\"\u003e\n\u003cp data-start=\"1848\" data-end=\"1928\"\u003e\u003cstrong data-start=\"1848\" data-end=\"1885\"\u003eHazardous industrial environments\u003c\/strong\u003e with compliance for CSA, ATEX, and IECEx\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1930\" data-end=\"1933\"\u003e\n\u003ch2 data-start=\"1935\" data-end=\"1951\"\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp data-start=\"1953\" data-end=\"2262\"\u003e\u003cstrong data-start=\"1953\" data-end=\"2002\"\u003eQ: Why is the 12.4 m system length important?\u003c\/strong\u003e\u003cbr data-start=\"2002\" data-end=\"2005\"\u003eA: The Proximitor sensor is calibrated for a specific total electrical length (5 m, 9 m, or custom lengths like 12.4 m). Maintaining the combined length of the probe lead and any extension cable ensures \u003cstrong data-start=\"2208\" data-end=\"2234\"\u003eaccuracy and linearity\u003c\/strong\u003e in vibration measurement.\u003c\/p\u003e\n\u003cp data-start=\"2264\" data-end=\"2580\"\u003e\u003cstrong data-start=\"2264\" data-end=\"2339\"\u003eQ: Can this probe be adjusted or replaced while the machine is running?\u003c\/strong\u003e\u003cbr data-start=\"2339\" data-end=\"2342\"\u003eA: Yes, when installed in a \u003cstrong data-start=\"2370\" data-end=\"2403\"\u003e21000 series external housing\u003c\/strong\u003e, the probe can often be \u003cstrong data-start=\"2428\" data-end=\"2463\"\u003eadjusted or replaced externally\u003c\/strong\u003e, without exposing technicians to moving parts—provided proper \u003cstrong data-start=\"2526\" data-end=\"2564\"\u003esafety protocols and housing seals\u003c\/strong\u003e are followed.\u003c\/p\u003e\n\u003cp data-start=\"2582\" data-end=\"2823\"\u003e\u003cstrong data-start=\"2582\" data-end=\"2633\"\u003eQ: Why choose a 16 mm probe over an 8 mm probe?\u003c\/strong\u003e\u003cbr data-start=\"2633\" data-end=\"2636\"\u003eA: The 16 mm probe offers a \u003cstrong data-start=\"2664\" data-end=\"2694\"\u003ewider linear range (~4 mm)\u003c\/strong\u003e, essential for machines with \u003cstrong data-start=\"2724\" data-end=\"2770\"\u003elarge shaft movements or thermal expansion\u003c\/strong\u003e, where standard 8 mm probes would be insufficient.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46253584711818,"sku":"21000-16-10-00-124-03-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0698\/2818\/2154\/files\/21000-16-05-00-094-03-02_fuben_7b67d35c-974f-4249-bb6c-a0d0a41aeee7.jpg?v=1745742241","url":"https:\/\/www.cambiaplc.com\/products\/bently-nevada-21000-16-10-00-124-03-02-vibration-sensor","provider":"Controlix Automation","version":"1.0","type":"link"}